  • Specification:

    The 754 is everything you needed and wished for in the 744 and more! HART communication capability is combined to deliver an integrated communicating calibrator. This rugged, reliable tool is ideal for calibrating, maintaining, and troubleshooting HART and other instrumentation.

    The 754 does the work of several tools - sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device. You’ll fall in love with the new improved graphical screen, Li-Ion battery for longer life, USB port and new accessories to complete the package.

    For documentation, the 754 automates calibration procedures and captures your data. And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations.

    HART Capabilities

    The 754 is designed to take on nearly all the day-to-day tasks you now perform with a separate communicator. In fact, it offers most of the communication capabilities of a HART communicator.

    To create a seamless/paperless calibration management system consider adding Fluke DPCTrack2 Calibration Management software for use with your Fluke 753 and 754 or even legacy Fluke 743 and 744 calibrators.

    The Fluke 754 Documenting Process Calibrator-HART: Work smarter. Work faster.


     


    Work smarter. Work faster.

    The 754 is a power multifunction documenting calibrator that lets you download procedures, lists, and instructions created with software-or upload data for printing, archiving, and analysis. The 754 also features a powerful built in HART® interface capable of performing nearly all the day-to-day tasks you now perform with a separate communicator.

    • Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
    • Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
    • Power transmitters during test using loop supply with simultaneous mA measurement
    • Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
    • Create and run automated as-found/as-left procedures to satisfy quality programs or regulations. Record and document results
    • Holds up to a full week of downloaded procedures and calibration results.
    • Use many features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay etc.
    • Easy to use
    • Three year warranty
    • Bright white dual display. Read both sourced and measured parameters simultaneously.
    • Multi lingual interface
    • Rechargeable Li-Ion battery for 10 hour uninterrupted use. Includes gas gauge.
    • Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1 ms.
    • Delivered with DPC/Track Sample software.
    • Compatible with many Asset Management software packages.

    HART Capabilities 
    The 754 is designed to take on nearly all the day-to-day tasks you now perform with a separate communicator. In fact, it offers the communication capabilities of the 375 HART communicator.

    • Requires no external box or second tool for everyday HART calibration and maintenance.
    • Offers fast HART communication.
    • Supports popular models of HART transmitters, with more devise-specific command support than any other HART field calibrator.
    • Works with multiple masters, burst mode, and multi-drop configurations.
    • Is easy to update as additional instruments are added and new HART versions are released.
    • Interrogate to determine device type, manufacturer, model, tag.
    • Reconfigure the sensor mapping of dual sensor temperature transmitters.
    • Read HART PV function and smart transmitter digital output while measuring analog mA output.
    • Read and write HART configuration functions to make field adjustments to PV range points, damping, and other top-level configuration settings.
    • Re-label smart transmitters by reading and writing to the HART tag field.

    Versatile HART Protocol support


    ManufacturerPressure instrumentsTemperature instrumentsCoriolis instruments
    ABB/Kent-Taylor600T658T1 
    ABB/Hartmann & BraunContrans P1,
    AS 800 Series
      
    Endress & HauserCERABAR S,
    CERABAR M,
    DELTABAR S
    TMT 1221,TMT 1821,
    TMT 1621
     
    Foxboro Eckardt TI/RTT201 
    Foxboro/InvensysI/A Pressure  
    FujiFCX
    FCXAZ
    FRC 
    HoneywellST3000STT25T1,
    STT25H1
     
    Micro Motion  2000
    2000 IS
    9701
    9712
    9739
    Moore Products 3441 
    Rosemount1151
    2088
    3001C
    3051, 3051S
    3044C
    644
    3144
    3244, 3144P
     
    SiemensSITRANS P DS
    SITRANS P ES
      
    SMARLD301TT3011 
    ViatranI/A Pressure  
    WikaUNITRANST32H1 
    YokogawaEJAYTA 110, 310 
    and 320
     


    1Sensor Trim not supported

    The 754 supports the commands contained in HART protocol Version 5.7. With 2 MB of memory, the 754 supports a substantial set of HART instructions:

    • Universal commands provide functions that are implemented in all field devices, for example, read manufacturer and device type, read primary variable (PV), or read current output and percent of span.
    • Common practice commands provide functions that are common to many but not all field devices, for example read multiple variables, set damping time, or perform loop test.
    • Device-specific commands provide functions that are unique to a particular field device, for example sensor trim.

    HART Operating Modes Supported

    • Point to Point operation , the most commonly used mode, connects the 754 to a single HART device in a 4-20 mA loop.
    • In Multi-Drop mode , several HART instruments can be bussed together. The 754 searches for each, identifies addresses in use, and allows you to select the instrument for calibration and related operations.
    • In Burst Mode, the HART instrument transmits bursts of data without waiting to be interrogated by a master unit. The 754 can take transmitters out of burst mode during test or calibration, then later restore them to burst mode.

    Pressure Modules

    Covers virtually any pressure application including gauge, differential, dual (compound), absolute, and vacuum.

    • Display pressure readings in any of 10 different pressure units you specify in the calibrator setup.
    • Rugged urethane molded cases protect the modules from rough handling and harsh conditions.
    • Features internal temperature compensation from 0° to 50°C for full accuracy performance.
    • Includes NIST-traceable calibration certificate.
    • Modules can be calibrated locally, helping to control costs.

    A family of 29 optional pressure modules provides pressure calibration and measurement capabilities. Twenty-eight modules are available, with basic accuracy specs to 0.05%. Ranges start at 0 – 1 inH20 (0 – .25kPa) and go to 0 – 10,000 psi (0 – 70,000 kPa). Additional information about pressure modules is available on the Pressure Modules Home Page.

    Automated Procedures

    Allow you to quickly set up powerful, automated calibration procedures for linear transmitters, DP flow transmitters, and one- and two-point limit switches. Simply select the appropriate measure and/or source functions and fill out the procedure template. The 750 Series does the rest. It quickly performs the test, calculates the errors, and displays the final results, highlighting out of tolerance points.

    Custom Units

    Enable you to map one unit to another, such as mV to °C or °F. Allows you to use the Fluke 750 Series with millivolt output accessories such as the Fluke 80T-IR Temperature Probe, and to document tests using non-supported units such as parts per million or revolutions per minute.

    User-entered Values

    Enables technicians to record calibration results that were sourced and/or measured by other devices such as panel meters or readout-only devices.

    Limit Switch Calibration

    Procedures perform fast, automated calibration of one and two-point limit switches for voltage, current, temperature, and pressure.

    Differential Pressure Flow Instrument Calibration

    Routines use a square root function to directly calibrate DP flow instruments.

    Additional Features 
    Multifunctional

    Calibrate temperature, pressure, voltage, current, resistance, and frequency. Since it both measures and sources, you can troubleshoot and calibrate all with one rugged tool.

    Powerful, yet easy to use

    The easy-to-follow menu-driven display guides you through any task. Get up to speed in minutes, not days. Programmable calibration routines enable you to create and run automated as-found/as-left procedures to ensure fast, consistent, calibrations.

    Records and documents results

    To support your ISO-9000 or regulatory standards the Fluke 754 captures your calibration results, eliminating the need to juggle a pen and pad in the field. The USB interface lets you transfer the results to a PC, thus saving the time of having to manually transcribe them when you return to the shop.

    Truly hand-held

    Small enough to fit easily into a tool bag and to use in tight spaces. Runs an entire shift on a rechargeable Li-ion battery pack.

    Rugged and reliable

    Count on Fluke's rugged design to deliver top accuracy and reliability in harsh environments. Overmolded urethane case stands up to rough handling in industrial environments.

    Bright white display

    Lets you read your results in any kind of light. Backlight has three (3) settings.

    Soft keys

    Provide one-touch access to enhanced functions such as task lists, automated procedures, scaling, min/max, stepping and ramping, and review memory.

    Three operating modes

    Measure, Source, or simultaneous Measure/Source, - enable technicians to troubleshoot, calibrate, or maintain instrumentation with just one tool.

    Multi-lingual interface

    Displays instructions in English, French, German, Spanish, and Italian.

    Built-in algebraic calculator

    With four functions-plus square root-stores, recalls, and performs calculations required for setting up instruments or evaluating data in the field. Use it to set the source function to a calculated value. There's no need to carry a pencil and paper or a separate calculator.

    Programmable measurement delay

    Inside automated procedures permits calibrating instruments that respond slowly.


    Measurement Accuracy
    Voltage DCRange/Resolution1 Year2 Years
    100.000 mV0.02% + 0.005 mV0.03% + 0.005 mV
    3.00000 V0.02% + 0.00005 V0.03% + 0.00005 V
    30.0000 V0.02% + 0.0005 V0.03% + 0.0005 V
    300.00 V0.05% + 0.05 V0.07% + 0.05 V
    Voltage AC3.000 V (40 Hz to 500 Hz) / 0.001 V0.5% + 0.002 V1.0% + 0.004 V
    30.00 V (40 Hz to 500 Hz) / 0.01 V0.5% + 0.02 V1.0% + 0.04 V
    300.0 V (40 Hz to 500 Hz) / 0.1 V0.5% + 0.2 V1.0% + 0.2 V
    Current DC30.000 mA0.01% + 5 uA0.015% + 7 uA
    110.00 mA0.01% + 20 uA0.015% + 30 uA
    Resistance10.000 Ω0.05% + 50 mΩ0.07% + 70 mΩ
    100.00 Ω0.05% + 50 mΩ0.07% + 70 mΩ
    1.0000 kΩ0.05% + 500 mΩ0.07% + 0.5 Ω
    10.000 kΩ0.1% + 10 Ω0.15% + 15 Ω
    Frequency1.00 to 110.00 Hz / 0.01 Hz
    0.05 Hz
    110.1 to 1100.0 Hz / 0.1 Hz
    0.5 Hz
    1.101 to 11.000 kHz / 0.001 kHz
    0.005 kHz
    11.01 to 50.00 kHz / 0.01 kHz
    0.05 kHz
    Source Accuracy


    1 Year2 Years
    Voltage DC100.000 mV0.01% + 0.005 mV0.015% + 0.005 mV
    1.00000 V0.01% + 0.00005 V0.015% + 0.0005 V
    15.0000 V0.01% + 0.0005 V0.015% + 0.0005 V
    Current DC22.000 mA (source)0.01% + 0.003 mA0.02% + 0.003 mA
    Current sink (simulate)0.02% + 0.007 mA0.04% + 0.007 mA
    Resistance10.000 Ω0.01% + 10 mΩ0.015% + 15 mΩ
    100.00 Ω0.01% + 20 mΩ0.015% + 30 mΩ
    1.0000 kΩ0.02% + 0.2 Ω0.03% + 0.3 Ω
    10.000 kΩ0.02% + 3 Ω0.03% + 5 Ω
    Frequency0.1 to 10.99 Hz
    0.01 Hz
    0.01 to 10.99 Hz
    0.01 Hz
    11.00 to 109.99 Hz
    0.1 Hz
    110.0 to 1099.9 Hz
    0.1 Hz
    1.100 to 21.999 kHz
    0.002 kHz
    22.000 to 50.000 kHz
    0.005 kHz
    Technical Data
    Data log functionsMeasure functionsVoltage, current, resistance, frequency, temperature, pressure
    Reading rate1, 2, 5, 10, 20, 30, or 60 readings/minute
    Maximum record length8000 readings (7980 for 30 or 60 readings/minute)
    Ramp functionsSource functionsVoltage, current, resistance, frequency, temperature
    Rate4 steps/second
    Trip detectContinuity or voltage (continuity detection not available when sourcing current)
    Loop power functionVoltageSelectable, 26 V
    Accuracy10%, 18 V minimum at 22 mA
    Maximum current25 mA, short circuit protected
    Maximum input voltage50 V DC
    Step functionsSource functionsVoltage, current, resistance, frequency, temperature
    Manual stepSelectable step, change with arrow buttons
    AutostepFully programmable for function, start delay, stepvalue, time per step, repeat
    Environmental Specifications
    Operating temperature-10°C to +50°C
    Storage temperature-20°C to +60°C
    Dust/water resistanceMeets IP52, IEC 529
    Operating altitude3000 m above mean sea level (9842 ft)
    Safety Specifications
    Agency approvalsCAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993
    Mechanical and General Specifications
    Size136 x 245 x 63 mm (5.4 x 9.6 x 2.5 in)
    Weight1.2 kg (2.7 lb)
    BatteriesInternal Battery Pack Li-ion: 7.2V,4400mAh, 30 Wh
    Battery life>8 hours typical
    Battery replacementReplace without opening calibrator; no tools required
    Side port connectionsPressure module connector
    USB Connector to interface to your PC
    Digital instrument (HART) connector
    Connection for optional battery charger/eliminator
    Data storage capacity1 week of calibration procedures results
    90 day specificationsThe standard specification interval for the 750 Seriesare 1 and 2 years.
    Typical 90 day measurement and source accuracy can be estimated by dividing the one year "% of reading" or "% of output" specifications by 2.
    Floor specifications, expressed as "% of full scale" or "counts" or "ohms" remain constant.
    Temperature, Resistance Temperature Detectors
    Degrees or % of reading - Type (α)Range °CMeasure °C1

    1 year2 year
    100 Ω Pt (385)-200 to 100
    100 to 800
    0.07°C
    0.02% + 0.05°C
    0.14°C
    0.04% + 0.10°C
    200 Ω Pt (385)-200 to 100
    100 to 630
    0.07°C
    0.02% + 0.05°C
    0.14°C
    0.04% + 0.10°C
    500 Ω Pt (385)-200 to 100
    100 to 630
    0.07°C
    0.02% + 0.05°C
    0.14°C
    0.04% + 0.10°C
    1000 Ω Pt (385)-200 to 100
    100 to 630
    0.07°C
    0.02% + 0.05°C
    0.14°C
    0.04% + 0.10°C
    100 Ω Pt (3916)-200 to 100
    100 to 630
    0.07°C
    0.02% + 0.05°C
    0.14°C
    0.04% + 0.10°C
    100 Ω Pt (3926)-200 to 100
    100 to 630
    0.08°C
    0.02% + 0.06°C
    0.16°C
    0.04% + 0.12°C
    10 Ω Cu (427)-100 to 2600.2°C0.4°C
    120 Ω Ni (672)-80 to 2600.1°C0.2°C
    Source currentSource °CAllowable current2

    1 year2 year
    1 mA0.05°C
    0.0125% + 0.04°C
    0.10°C
    0.025% + 0.08°C
    0.1 mA to 10 mA
    500 μA0.06°C
    0.017% + 0.05°C
    0.12°C
    0.034% + 0.10°C
    0.1 mA to 1 mA
    250 μA0.06°C
    0.017% + 0.05°C
    0.12°C
    0.034% + 0.10°C
    0.1 mA to 1 mA
    150 μA0.06 C
    0.017% + 0.05°C
    0.12 C
    0.034% + 0.10°C
    0.1 mA to 1 mA
    1 mA0.05°C
    0.0125% + 0.04°C
    0.10°C
    0.025% + 0.08°C
    0.1 mA to 10 mA
    1 mA0.05°C
    0.0125% + 0.04°C
    0.10°C
    0.025% + 0.08°C
    0.1 mA to 10 mA
    3 mA0.2°C0.4°C0.1 mA to 10 mA
    1 mA0.04°C0.08°C0.1 mA to 10 mA
    1. For two and three-wire RTD measurements, add 0.4°C to the specifications.
    2. Supports pulsed transmitters and PLCs with pulse times as short as 1 ms
    Temperature, Thermocouples
    TypeSource °CMeasure °CSource °C


    1 year2 years1 year2 years
    E-250 to -2001.32.00.60.9
    -200 to -1000.50.80.30.4
    -100 to 6000.30.40.30.4
    600 to 10000.40.60.20.3
    N-200 to -1001.01.50.60.9
    -100 to 9000.50.80.50.8
    900 to 13000.60.90.30.4
    J-210 to -1000.60.90.30.4
    -100 to 8000.30.40.20.3
    800 to 12000.50.80.30.3
    K-200 to -1000.71.00.40.6
    -100 to 4000.30.40.30.4
    400 to 12000.50.80.30.4
    1200 to 13720.71.00.30.4
    T-250 to -2001.72.50.91.4
    -200 to 00.60.90.40.6
    0 to 4000.30.40.30.4
    B600 to 8001.32.01.01.5
    800 to 10001.01.50.81.2
    1000 to 18200.91.30.81.2
    R-20 to 02.32.81.21.8
    0 to 1001.52.21.11.7
    100 to 17671.01.50.91.4
    S-20 to 02.32.81.21.8
    0 to 2001.52.11.11.7
    200 to 14000.91.40.91.4
    1400 to 17671.11.71.01.5
    C0 to 8000.60.90.60.9
    800 to 12000.81.20.71.0
    1200 to 18001.11.60.91.4
    1800 to 23162.03.01.32.0
    L-200 to -1000.60.90.30.4
    -100 to 8000.30.40.20.3
    800 to 9000.50.80.20.3
    U-200 to 00.60.90.40.6
    0 to 6000.30.40.30.4
    BP0 to 10001.01.50.40.6
    1000 to 20001.62.40.60.9
    2000 to 25002.03.00.81.2
    XK-200 to 3000.20.30.20.5
    300 to 8000.40.60.30.6


    Includes:

    • BC7240 battery charger
    • Li-on BP7240 battery pack
    • Instruction manual
    • Three sets of TP220 test probes with three sets of “extended tooth" alligator clips
    • Two sets AC280 hook clips
    • C799 Soft Field Case
    • USB communication cable, Fluke 754HHC HART communications cable




Price

  • Delivery Port : KLIA

Packaging & Delivery

  • Packing :Original
  • Delivery Lead Time : 2-3

Product Image

  • 1Fluke 754 Documenting Process Calibrator and Hart Instrumentation image 1
  • 2 Fluke 754 Documenting Process Calibrator and Hart Instrumentation image 2
  • 3 Fluke 754 Documenting Process Calibrator and Hart Instrumentation image 3
  • 4 Fluke 754 Documenting Process Calibrator and Hart Instrumentation image 4
  • 5 Fluke 754 Documenting Process Calibrator and Hart Instrumentation image 5
  • 6 Fluke 754 Documenting Process Calibrator and Hart Instrumentation image 6

Send an Inquiry to this supplier

Send an Inquiry to this supplier
* From
  To Endang
Endang Surveying Sdn.Bhd
* Buying Product
- Please enter your specific buying item.
e.g. 42 inch LCD TV, leather executive chair
Category : Testing Equipment
* Message

Use English only Max. 2000 characters. (Min. 20)

Send
EC21.com does not guarantee the validity of product information or the credentials of sellers.

Browse: Manufacturer Directory Premium Suppliers Site Map

About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy

Copyright (c)1997-2026 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese

Business Registry Number: 120-86-03931 | Mall order sales Registration Number: 강남-5838